CS401- Computer Architecture and Assembly Language
Quiz No.4 FEB 14, 2013
A 32-bit address register can access up to ____ of memory.
2 MB
2 GB
4 MB
4 GB
Operating system Organize data in the form of
Folder
Batch file
File
None of the above
The 'program segment prefix' for com files is of size:
Select correct option:
64 bytes
128 bytes
256 bytes
512 bytes
COM1 is connected with
IRQ2
IRQ3
IRQ4
IRQ5
"INT13 –BIOS disk services" generally uses which register to return the 'error flag' ?
Select correct option:
CF
DL
AH
AL
In case of COM file, first command line parameter is stored at ___ offset of 'program segment prefix'
0×80
0×82
0×84
0×86
On executing INT 0×21 service 0x3D, if file is successfully opened then
CF will contain 1
CF will contain 0
ZF will contain 1
ZF will contain 0
Which register is generally used to specify the service number of an interrupt ?
AX
BX
CX
The lower 16-bits of EAX register are labeled as:
EAL
AL
AH
AX
Device drivers can be divided into ___ major categories:
3
4
2
None
In programmable interrupt controller which of the following ports is referred as a
interrupt mask register?
Select correct option:
19
20
21
22
Which of the following BIOS INT provides serial port services
INT 21
INT 14
INT 10
INT 08
In 9pin DB 9 connector, which pin is assigned to RD (Received Data) ?
1
2
3
4
In 9pin DB 9 connector, which pin is assigned to Signal Ground ?
3
4
5
6
Device drivers can be divided into ___ major categories:
5
4
3
2
The INT 0x13 service 0x03 is use to
Select correct option:
Get drive parameter
Reset disk sector
Write disk sector
Read disk sector
Hard disk MBR( Master Boot Record ) is of size_____.
Select correct option:
446 bytes
350 bytes
512 bytes
256 bytes
COM2 is connected with
Select correct option:
IRQ 2
IRQ 3
IRQ 4
IRQ 5
On executing INT 0x21--service 0x3D, if file can't be opened then
Select correct option:
CF will contain 1
CF will contain 0
ZF will contain 1
ZF will contain 0
"INT13 --BIOS disk services" generally uses which register to return the 'error code' ?
correct option:
CF
DL
AH
AL
BPB stands for
Basic parameter block
Bios precise block
Basic precise block
Bios parameter block
"INT13 --BIOS disk services" generally uses which register to return the 'error flag' ?
CF
DL
AH
AL
The maximum length of DOS command line parameters is
64 bits
127 bits
256 bits
512 bits
Which of the following BIOS INT provides serial port services
Select correct option:
INT 21
INT 14
INT 10
INT 08
In case of COM file, maximum length of parameters passed through command line can be ___
Select correct option:
63 bytes
127 bytes
255 bytes
511 bytes
In case of COM file, first command line parameter is stored at ___ offset of 'program segment prefix'
Select correct option:
0x80
0x82
0x84
0x86
The 'program segment prefix' is used to store:
Select correct option:
DOS information
Command tail
DOS information and Command tail
None of the given options
The INT 0x13 service 0x03 is use to
Select correct option:
Read disk sector
Write disk sector
Reset disk sector
Get drive parameter
On executing INT 0x21--service 0x3D, if file can't be opened then
Select correct option:
CF will contain 1
CF will contain 0
ZF will contain 1
ZF will contain 0
Operating system Organize data in the form of
Select correct option:
Folder
Batch file
File
None of the above
We can access all the DOS services using
Select correct option:
INT 0x21
INT 0x13
INT 0x10
INT 0x08
In 9pin DB 9 connector, which pin is assigned to RD (Received Data) ?
Select correct option:
1
2
3
4
Device drivers can be divided into ___ major categories:
Select correct option:
5
4
3
2
The higher 16-bits of EAX register are labeled as:
Select correct option:
AX
EAH
AH
None of the given options
Ist woh jiss ney tumhari jeet ke Liye buhat kuch hara hoo
--
-------------------------------------------------------------
"VU CLUB" | Learning and Entertainment |
-------------------------------------------------------------
For study material join VU Club at:
http://vuclub.net & http://vuforum.net
To post to this group, send email to:
vu-club@googlegroups.com
For more options, visit this group at
http://groups.google.com/group/vu-club?hl=en?hl=en
Join us on Facebook:
http://www.facebook.com/#!/groups/190713217644560/
---
You received this message because you are subscribed to the Google Groups "VU CLUB" group.
To unsubscribe from this group and stop receiving emails from it, send an email to vu-club+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
No comments:
Post a Comment